Sophie

Sophie

distrib > Mageia > 6 > x86_64 > media > core-release > by-pkgid > 479824ecf6b3f1e9e6111e98714c3ca3 > files > 194

argyllcms-1.9.2-1.mga6.x86_64.rpm

<!DOCTYPE html PUBLIC "-//W3C//DTD HTML 4.01 Transitional//EN">
<html>
  <head>
    <title>chartread</title>
    <meta http-equiv="content-type" content="text/html;
      charset=windows-1252">
    <meta name="author" content="Graeme Gill">
  </head>
  <body>
    <h2><b>spectro/chartread</b></h2>
    <h3>Summary</h3>
    Read a printer test chart using an instrument, to create a&nbsp;<a
      href="File_Formats.html#.ti3">.ti3</a> data file. The type of
    instrument is determined by the communication port selected.<br>
    <br>
    <span style="font-weight: bold;">chartread</span> can also be used
    to read transmission values, and to read display values manually.<br>
    <h3>Usage</h3>
    <small><span style="font-family: monospace;">chartread [-options]
        outfile</span><br style="font-family: monospace;">
      <span style="font-family: monospace;">&nbsp;</span><a
        style="font-family: monospace;" href="#v">-v</a><span
        style="font-family: monospace;">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
&nbsp;
&nbsp;
Verbose






        mode</span><br style="font-family: monospace;">
      <span style="font-family: monospace;">&nbsp;</span><a
        style="font-family: monospace;" href="#c">-c listno</a><span
        style="font-family: monospace;"> &nbsp; &nbsp;&nbsp;
        &nbsp;&nbsp;&nbsp; Set communication port from the following
        list (default 1)</span><br style="font-family: monospace;">
      <span style="font-family: monospace;">&nbsp;</span><a
        style="font-family: monospace;" href="#t">-t</a><span
        style="font-family: monospace;">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
&nbsp;&nbsp;
Use
transmission






        measurement mode<br>
      </span></small><small><span style="font-family: monospace;">&nbsp;</span><a
        style="font-family: monospace;" href="#d">-d</a><span
        style="font-family: monospace;">
        &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
Use
display
measurement






        mode (white Y relative results)</span></small><small><span
        style="font-family: monospace;"></span></small><small><span
        style="font-family: monospace;"><br>
        &nbsp;</span></small><font size="-1"><span style="font-family:
        monospace;"><a href="#y">-y X</a>
        &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;






        Display type - instrument specific list to choose from.</span></font><br>
    <small><span style="font-family: monospace;">&nbsp;</span><a
        style="font-family: monospace;" href="#e">-e</a><span
        style="font-family: monospace;">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
Use
emissive&nbsp;
measurement






        mode (absolute results)<br>
      </span></small><small><span style="font-family: monospace;">&nbsp;</span><a
        style="font-family: monospace;" href="#p">-p</a><span
        style="font-family: monospace;">
        &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
Measure
patch
by






        patch rather than strip</span></small><br>
    <small><span style="font-family: monospace;"></span>&nbsp; <a
        style="font-family: monospace;" href="#x">-x [lx]</a><span
        style="font-family: monospace;">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
Take



        manually entered values, either L*a*b* (-xl) or XYZ (-xx).</span><br
        style="font-family: monospace;">
      <span style="font-family: monospace;">&nbsp;</span><a
        style="font-family: monospace;" href="#n">-n</a><span
        style="font-family: monospace;">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
&nbsp;
&nbsp;
Don't






        save spectral information (default saves spectral)<br>
      </span></small><small><span style="font-family: monospace;">&nbsp;</span><a
        style="font-family: monospace;" href="#l">-l</a><span
        style="font-family: monospace;">
        &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
        &nbsp; &nbsp; Save CIE as D50 L*a*b* rather than XYZ<br>
      </span></small><small><span style="font-family: monospace;">&nbsp;</span><a
        style="font-family: monospace;" href="#L">-L</a><span
        style="font-family: monospace;">
        &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
        &nbsp; &nbsp; Save CIE as D50 L*a*b* as well as XYZ</span></small><br>
    <small><span style="font-family: monospace;">&nbsp;<a href="#r">-r</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
Resume
reading
partly






        read chart<br>
        &nbsp;<a href="#I">-I</a>
        file.cal&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Override
        calibration info from .ti2 in resulting .ti3<br>
        &nbsp;</span></small><font size="-1"><span style="font-family:
        monospace;"><a href="#F">-F filter</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;






        Set filter configuration:<br>
        &nbsp;
        n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;






        None<br>
        &nbsp;
        p&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;






        Polarising filter<br>
        &nbsp;
        6&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;






        D65<br>
        &nbsp;
        u&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;






        U.V. Cut</span></font><small><span style="font-family:
        monospace;"></span><span style="font-family: monospace;"></span></small><br>
    &nbsp; <font size="-1"><span style="font-family: monospace;"><a
          href="#A">-A N|A|X|G</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;

        XRGA conversion</span></font> (default N)<br>
    <font size="-1"><span style="font-family: monospace;">&nbsp;</span><a
        style="font-family: monospace;" href="#N">-N</a><span
        style="font-family: monospace;">
        &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
        &nbsp;&nbsp; Disable initial calibration of instrument unless
        essential<br>
      </span></font><font size="-1"><span style="font-family:
        monospace;">&nbsp;</span><a style="font-family: monospace;"
        href="#B">-B</a><span style="font-family: monospace;">
        &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
        &nbsp;&nbsp; Disable auto bi-directional strip recognition</span></font><br>
    <font size="-1"><span style="font-family: monospace;">&nbsp;</span><a
        style="font-family: monospace;" href="#H">-H</a><span
        style="font-family: monospace;">
        &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
        &nbsp;&nbsp; Use high resolution spectrum mode (if available)<br>
      </span></font><font size="-1"><span style="font-family:
        monospace;">&nbsp;</span></font><font size="-1"><span
        style="font-family: monospace;"><a href="#X1">-X file.ccmx</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;







        Apply Colorimeter Correction Matrix</span></font><br>
    <span style="font-family: monospace;">&nbsp;<a href="#X2">-X
        file.ccss</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
Use
Colorimeter
Calibration
Spectral
Samples







      for calibration</span><br>
    <small><span style="font-family: monospace;">&nbsp;</span><a style="
        font-family: monospace;" href="#Q">-Q observ</a><span
        style="font-family: monospace;">&nbsp; &nbsp; &nbsp;
        &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Choose CIE Observer for
        spectral data or CCSS instrument:</span><br style="font-family:
        monospace;">
      <span style="font-family: monospace;">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;







        &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp; </span></small><small><span
        style="font-family: monospace;">1931_2 </span></small><small><span
        style="font-family: monospace;"> (def.)</span></small><small><span
        style="font-family: monospace;">, 1964_10, S&amp;B 1955_2, shaw,
        J&amp;V 1978_2</span></small><small><span style="font-family:
        monospace;"></span></small><font size="-1"><span
        style="font-family: monospace;"></span></font><br>
    <font size="-1"><span style="font-family: monospace;"> &nbsp;<a
          href="#T">-T ratio</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
Modify
strip
patch






        consistency tolerance by ratio (if available)<br>
      </span></font><font size="-1"><span style="font-family:
        monospace;">&nbsp;<a href="#S">-S</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
Suppress
wrong
strip






        &amp; unexpected value warnings</span></font><br>
    <font size="-1"><span style="font-family: monospace;">&nbsp;<a
          href="#W">-W n|h|x</a>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
Override






        serial port flow control: n = none, h = HW, x = Xon/Xoff</span></font><br
      style="font-family: monospace;">
    <small><span style="font-family: monospace;"></span><small
        style="font-family: monospace;">&nbsp;<a href="#D">-D [level]</a>
        &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Print debug
        diagnostics to stderr</small><br style="font-family: monospace;">
      <span style="font-family: monospace;">&nbsp;</span><a
        style="font-family: monospace;" href="#p1"><i>inoutfile</i></a><span
        style="font-family: monospace;">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;






        &nbsp;Base name for input[</span><a style="font-family:
        monospace;" href="File_Formats.html#.ti2">.ti2</a><span
        style="font-family: monospace;">]/output[</span><a
        style="font-family: monospace;" href="File_Formats.html#.ti3">.ti3</a><span
        style="font-family: monospace;">] file</span></small> <br>
    <h3>Usage Details</h3>
    <a name="v"></a>The <b>-v</b> flag causes extra information to be
    printed out during chartread operation.<br>
    <br>
    <a name="c"></a>Normally instruments are connected via a serial
    communication port, and the port used should be selected by
    supplying the correct parameter to the <b>-c</b> flag. If you
    invoke <span style="font-weight: bold;">chartread</span> so as to
    display the usage information (i.e. "chartread -?" or "chartread
    --"), then the discovered serial ports will be listed on Windows and
    Mac OSX systems.<br>
    <br>
    <a name="t"></a>If using an Xrite DTP41T, and printing onto
    transparent or back lit media, use the <b>-t</b> flag to operate
    the instrument in transparency mode. If using a Spectrolino or
    Eye-One Pro (handheld), this triggers a fake transparency mode, that
    uses a separate backlight (such as a light box). The&nbsp;
    instrument will be used to calibrate the level of backlight, and use
    this to compute the transparency of the test chart samples. Note
    that for good transparency values, the backlight level needs to be
    neither too bright not too dark, should ideally be incandescent
    rather than fluorescent (since fluorescent lights often have big
    dips in their spectrum), and ideally should be of uniform brightness
    over the measurement area. If using the SpectroScanT, the <span
      style="font-weight: bold;">-t</span> flag operates the instrument
    in transparency mode, each reading being manually triggered.<br>
    <br>
    <a name="d"></a>The <span style="font-weight: bold;">-d</span> flag
    allows measuring in display mode using instruments that support this
    mode, with the brightness normalized to the white patch value in the
    test chart. While the brightness values are then relative to the
    white, the readings are otherwise absolute. This corresponds to the
    raw ICC absolute readings created by <a href="dispread.html">dispread</a>,
    and is the mode that should be used for creating a normal display
    ICC profile using manual, spot by spot readings. This can be useful
    if the display cannot be driven directly by the computer, but can be
    made manually to display the test charts.<br>
    <br>
    <a name="y"></a>&nbsp; The <span style="font-weight: bold;">-y</span>
    flag allows setting the Display Type. The selection typically
    determines two aspects of of the instrument operation: <span
      style="font-weight: bold;">1)</span> It may set the measuring mode
    to suite <a
      href="http://en.wikipedia.org/wiki/Comparison_of_display_technology"><span
        style="font-weight: bold;">refresh</span> or <span
        style="font-weight: bold;">non-refresh</span> displays</a>.
    Typically only LCD (Liquid Crystal) displays have a non-refresh
    nature. <span style="font-weight: bold;">2)</span> It may select an
    instrument calibration matrix suitable for a particular display
    type. The selections available depends on the type and model of
    instrument, and a list of the options for the discovered instruments
    will be shown in the <a href="ArgyllDoc.html#CmdLine">usage</a>
    information. For more details on what particular instruments support
    and how this works, see <a href="instruments.html">Operation of
      particular instruments</a>. <b>3)</b> Any installed CCSS files
    (if applicable), or CCMX files. These files are typically created
    using <a href="ccxxmake.html">ccxxmake</a>, and installed using <a
      href="oeminst.html">oeminst</a>. The default and Base Calibration
    types will be indicated in the usage.<br>
    <br>
    <a name="e"></a> If using an instrument that supports an emissive
    measurement mode (such as the Spectrolino), then the <span
      style="font-weight: bold;">-e</span> flag enables this measurement
    mode, and the values recorded will be absolute XYZ values. This can
    be used for media such as backlit film, measuring it on a lightbox,
    so as to capture the actual illumination characteristics of that
    particular media. An adaptive integration time will be used in
    devices that support it. <br>
    <br>
    <a name="p"></a> The <span style="font-weight: bold;">-p</span>
    flag causes chartread to use a spot read mode for an instrument,
    even if it is capable of faster chart reading modes such as strip
    reading. This can be useful if strip measurement patch recognition
    is not reliable for certain media.<br>
    <br>
    <a name="x"></a> The <span style="font-weight: bold;">-x</span>
    flag causes chartread to expect values to be manually entered for
    each reading, rather than using an instrument to do the
    measurements.&nbsp; This mode is ideal if your instrument is not
    supported by Argyll. Either XYZ or L*a*b* values can be entered,
    depending on what option follows <span style="font-weight: bold;"><span
        style="font-weight: bold;">-l</span></span>, <span
      style="font-weight: bold;">-lx</span> to specify XYZ values, or <span
      style="font-weight: bold;">-ll</span> to specify L*a*b* values.
    XYZ values are expected to be scaled to a maximum of 100. It is
    possible to navigate about the test values being measured, so as to
    do them in any order, as well as re-do values, in case of any
    mistakes.<br>
    <br>
    <a name="n"></a> <span style="font-weight: bold;">-n</span> By
    default spectral information as well as D50 standard observer XYZ
    values will be recorded for each test patch, when such readings are
    available from a device. The spectral readings allow for choosing a
    non-standard viewing illuminant, a non-standard observer model, or
    the use of the Fluorescent Paper Whitener Additive compensation when
    creating the profile. If the spectral readings are not needed, then
    prinread operation can be speeded up by specifying the <b>-n</b>
    flag.<br>
    <br>
    <a name="l"></a> <span style="font-weight: bold;">-l</span> By
    default D50 standard observer XYZ values will be recorded for each
    test patch, but if the <span style="font-weight: bold;"><span
        style="font-weight: bold;">-l</span></span> flag is used, D50
    L*a*b* values will be recorded instead.<br>
    <br>
    <a name="L"></a> <span style="font-weight: bold;">-L</span> By
    default D50 standard observer XYZ values will be recorded for each
    test patch, but if the <span style="font-weight: bold;"><span
        style="font-weight: bold;">-L</span></span> flag is used, XYZ <span
      style="font-weight: bold;">and&nbsp;</span>D50 L*a*b* values will
    be recorded.<br>
    <br>
    <a name="r"></a> <span style="font-weight: bold;">-r</span> By
    default chartread reads the chart from scratch each time. When
    reading a chart using a strip instrument or patch by patch you can
    choose to finish chartread without reading all the patches, and
    whatever patches have been read will be saved to the output .ti3
    file. You can then <span style="text-decoration: underline;">resume</span>
    reading the patches by using the <span style="font-weight: bold;">-r</span>
    flag, in which case chartread will read the .ti3 file and set the
    patches to those previously read values, allowing any unread patches
    to then be read, or to re-read previously read patches.<br>
    <br>
    <a name="I"></a> <span style="font-weight: bold;">-I</span> <span
      style="font-style: italic;">file.cal</span>&nbsp; Normally per
    channel calibration curves are added to the .ti2 file using the <span
      style="font-weight: bold;">printtarg -K</span> or <span
      style="font-weight: bold;">-I</span> options, so that they will be
    passed on to the .ti3 file by&nbsp; <span style="font-weight:
      bold;">chartread</span>, so that <span style="font-weight: bold;">colprof</span>
    is able to correctly compute total ink limits. Where the calibration
    is being applied in a workflow with native calibration capability<small><span
        style="font-family: monospace;"></span></small> though, it is
    sometimes convenient to re-use a profile chart with different
    calibration curves without going through the process of using <span
      style="font-weight: bold;">printtarg</span> to re-create it. This
    would mean though, that the calibration information and subsequent
    ink limit calculations wouldn't be accurate. To overcome this and
    allow such a scenario, the <span style="font-weight: bold;">chartread





      -I</span> parameter allows overriding the .ti2 calibration curves
    placed in the resulting .ti3 file with the actual calibration that
    was used for that particular print.<br>
    <br>
    <a name="F"></a>The <b>-F</b> options allows configuring the
    instrument to have a particular filter fitted to it. Some
    instruments (i.e. the Gretag Spectrolino) allow the fitting of
    various filters, such as a polarizing filter, D65 illuminant
    simulation, or Ultra Violet Cut filter, and this option allows the
    instrument to be configured appropriately.<br>
    <br>
    <a name="A"></a>The <b>-A</b> options allows overriding the default
    or environment variable set <a href="XRGA.html">XRGA</a>
    conversion:<br>
    <br>
    &nbsp;&nbsp;&nbsp; <b>-A N|A|X|G</b><br>
    <br>
    &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; The <b>N</b> argument sets
    the calibration to Native (default).<br>
    &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; The <b>A</b> argument sets
    the calibration to XRGA.<br>
    &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; The <b>X</b> argument sets
    the calibration to XRDI.<br>
    &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; The <b>G</b> argument sets
    the calibration to GMDI.<br>
    <br>
    <a name="N"></a> <span style="font-weight: bold;">-N</span> Any
    instrument that requires regular calibration will ask for
    calibration on initial start-up. Sometimes this can be awkward if
    the instrument is being mounted in some sort of measuring jig, or
    annoying if several sets of readings are being taken in quick
    succession. The -<span style="font-weight: bold;">N</span>
    suppresses this initial calibration if a valid and not timed out
    previous calibration is recorded in the instrument or on the host
    computer. It is advisable to only use this option on the second and
    subsequent measurements in a single session.<br>
    <br>
    <a name="B"></a> <span style="font-weight: bold;">-B</span> Some
    strip instruments (i.e.. Eye-One Pro, Color Munki) when used with
    Argyll will automatically recognize a strip when read in the reverse
    direction by matching the patch readings against their expected
    values. If the expected values are not known accurately enough, this
    may cause erroneous reverse recognition, so the <span
      style="font-weight: bold;">-<span style="font-weight: bold;">B</span></span>
    flag allows this to be turned off, forcing strips to only be read in
    the forward direction. (Note that the DTP20 always allows
    bi-directional strip reading.) If the randomized patch layout has
    not been used, then&nbsp; bi-directional strip recognition will
    automatically turned off, and a warning issued if the -B flag is not
    used.<br>
    <br>
    <a name="H"></a> The -<span style="font-weight: bold;">H</span>
    option turns on high resolution spectral mode, if the instrument
    supports it. See <a href="instruments.html">Operation of particular
      instruments</a> for more details.<br>
    <br>
    <a name="X1"></a> The -<span style="font-weight: bold;">X <span
        style="font-style: italic;">file.ccmx</span></span> option reads
    a <a href="File_Formats.html#.ccmx">Colorimeter Correction Matrix</a>
    from the given file, and applies it to the colorimeter instruments
    readings. This can improve a colorimeters accuracy for a particular
    type of display. A list of contributed <span style="font-weight:
      bold;">ccmx</span> files is <a href="ccmxs.html">here</a>.<br>
    <br>
    <a name="X2"></a> The -<span style="font-weight: bold;">X <span
        style="font-style: italic;">file.ccss</span></span> option reads
    a <a href="File_Formats.html#.ccss">Colorimeter Calibration
      Spectral Sample</a> from the given file, and uses it to set the
    colorimeter instruments calibration. This will only work with
    colorimeters that rely on sensor spectral sensitivity calibration
    information (ie. the X-Rite <span style="font-weight: bold;">i1d3</span>,
    or the DataColor <span style="font-weight: bold;">Spyder4 &amp;
      Spyder 5</span>).This can improve a colorimeters accuracy for a
    particular type of display.<br>
    <br>
    <a name="T"></a> The -<span style="font-weight: bold;">T ratio</span>
    argument modifies the patch consistency tolerance threshold for some
    strip reading instruments (ie. the Eye-One Pro). In recognizing
    patches in a strip, an instrument may take multiple readings as the
    strip is read, and then divide the readings up into each patch. It
    may then check the consistency of the multiple readings
    corresponding to each patch, and reject the measurement if they are
    too inconsistent. For some media (ie. a coarser screens, fabric
    etc.) the default tolerance may be unreasonably tight, so the <span
      style="font-weight: bold;">-T ratio</span> argument can be used to
    modify this criteria. To loosen the tolerance, use a number greater
    than 1.0 (ie. 1.5, 2.0).<br>
    <br>
    <a name="Q"></a> The <b>-Q</b> flag allows specifying a tristimulus
    observer for a colorimeter when using CCSS instrument calibration
    capability. The following choices are available:<br>
    <b>&nbsp; 1931_2</b> selects the standard CIE 1931 2 degree
    observer. The default.<br>
    &nbsp; <b>1964_10</b> selects the standard CIE 1964 10 degree
    observer.<br>
    &nbsp; <b>1955_2</b> selects the Stiles and Birch 1955 2 degree
    observer<br>
    &nbsp; <b>1978_2 </b>selects the Judd and Voss 1978 2 degree
    observer<br>
    &nbsp; <b>shaw</b> selects the Shaw and Fairchild 1997 2 degree
    observer<br>
    <br>
    <a name="S"></a>The <b>-S</b> flag causes the normal "wrong strip"
    and "unexpected value" warnings to be suppressed. There may be a lot
    of these warnings if the expected patch value in the .ti2 file is in
    fact far from the values actually being measured. It is probably
    advisable to also use the <span style="font-weight: bold;">-B</span>
    flag if warnings are turned off, since many warnings indicate that
    the expected values are not to be relied on. With warnings
    suppressed, greater care must be taken to read the correct strip. If
    the randomized patch layout has not been used, then "wrong strip"
    warnings will automatically be suppressed, and bi-directional strip
    recognition turned off.<br>
    <br>
    <a name="W"></a>The <b>-W</b> <span style="font-weight: bold;">n|h|x</span>
    parameter overrides the default serial communications flow control
    setting. The value <span style="font-weight: bold;">n</span> turns
    all flow control off, <span style="font-weight: bold;">h</span>
    sets hardware handshaking, and <span style="font-weight: bold;">x</span>
    sets Xon/Xoff handshaking. This commend may be useful in workaround
    serial communications issues with some systems and cables. <br>
    <br>
    <a name="D"></a>The <b>-D</b> flag causes communications and other
    instrument diagnostics to be printed to stdout. A level can be set
    between 1 .. 9, that may give progressively more verbose
    information, depending on the instrument. This can be useful in
    tracking down why an instrument can't connect.<br>
    <br>
    <a name="p1"></a> The <i>inoutfile</i> parameters should be the
    base name of the .ti2 file, and chartread will output an .ti3 that
    has the same basename and the .ti3 extension. If the incoming .ti2
    file contains per-channel calibration curves, these will be passed
    through to the .ti3 so that accurate ink limits can be computed
    during profiling.<br>
    <br>
    <hr style="width: 50%; height: 2px;">
    <h3>Discussion</h3>
    For information about the operation of different instruments, see <a
      href="instruments.html">Operation of particular instruments</a>.<br>
    <br>
    <br>
  </body>
</html>