Sophie

Sophie

distrib > Mageia > 5 > i586 > by-pkgid > 37ce2601040f8edc2329d4714238376a > files > 4370

eso-midas-doc-13SEPpl1.2-3.mga5.i586.rpm

<!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 3.2 Final//EN">
<!--Converted with LaTeX2HTML 98.1p1 release (March 2nd, 1998)
originally by Nikos Drakos (nikos@cbl.leeds.ac.uk), CBLU, University of Leeds
* revised and updated by:  Marcus Hennecke, Ross Moore, Herb Swan
* with significant contributions from:
  Jens Lippmann, Marek Rouchal, Martin Wilck and others -->
<HTML>
<HEAD>
<TITLE>CCD photometry</TITLE>
<META NAME="description" CONTENT="CCD photometry">
<META NAME="keywords" CONTENT="vol2">
<META NAME="resource-type" CONTENT="document">
<META NAME="distribution" CONTENT="global">
<META HTTP-EQUIV="Content-Type" CONTENT="text/html; charset=iso-8859-1">
<LINK REL="STYLESHEET" HREF="vol2.css">
<LINK REL="previous" HREF="node631.html">
<LINK REL="up" HREF="node628.html">
<LINK REL="next" HREF="node633.html">
</HEAD>
<BODY >
<!--Navigation Panel-->
<A NAME="tex2html9397"
 HREF="node633.html">
<IMG WIDTH="37" HEIGHT="24" ALIGN="BOTTOM" BORDER="0" ALT="next"
 SRC="icons.gif/next_motif.gif"></A> 
<A NAME="tex2html9394"
 HREF="node628.html">
<IMG WIDTH="26" HEIGHT="24" ALIGN="BOTTOM" BORDER="0" ALT="up"
 SRC="icons.gif/up_motif.gif"></A> 
<A NAME="tex2html9390"
 HREF="node631.html">
<IMG WIDTH="63" HEIGHT="24" ALIGN="BOTTOM" BORDER="0" ALT="previous"
 SRC="icons.gif/previous_motif.gif"></A> 
<A NAME="tex2html9396"
 HREF="node1.html">
<IMG WIDTH="65" HEIGHT="24" ALIGN="BOTTOM" BORDER="0" ALT="contents"
 SRC="icons.gif/contents_motif.gif"></A>  
<BR>
<B> Next:</B> <A NAME="tex2html9398"
 HREF="node633.html">Observational data</A>
<B> Up:</B> <A NAME="tex2html9395"
 HREF="node628.html">Sample instrument files</A>
<B> Previous:</B> <A NAME="tex2html9391"
 HREF="node631.html">A modern two-channel photometer</A>
<BR>
<BR>
<!--End of Navigation Panel-->

<H3><A NAME="SECTION003257400000000000000">
CCD photometry</A>
</H3>
Our final example is an instrument-description file used for
B and V magnitudes extracted from CCD frames.
The CCD is a front-illuminated chip, run at 180 K.
The filters are at ambient temperature, uncontrolled.
Bands are identified by name in the file of extracted values.

<P>
The instrumental description is in Table&nbsp;<A HREF="node631.html#tbl:ccd-example">I.16</A>.
Notice how this resembles the primitive UBV photometer in the first example.

<P>
<BR><HR>
<ADDRESS>
<I>Petra Nass</I>
<BR><I>1999-06-15</I>
</ADDRESS>
</BODY>
</HTML>